Tardy Spinal Cord Compression without Bone Cement Leakage after Kyphoplasty: A Report of 3 Cases
Journal of Korean Society of Spine Surgery ; : 104-110, 2010.
Artigo em Coreano | WPRIM | ID: wpr-104012
ABSTRACT
STUDY

DESIGN:

This is a case report.

OBJECTIVE:

We report here on three cases of late spinal cord compression without bone cement leakage after kyphoplasty from the view point of the common characteristics, the suspected etiologies and the performed treatments, and we propose a technique to prevent this kind of complication. SUMMARY OF THE LITERATURE REVIEW Kyphoplasty is widely accepted as an effective and safe treatment for osteoporotic vertebral compression fracture (VCF). Complicated compression fractures and even bursting fractures with a compromised spinal canal are currently indicated for kyphoplasty. The wide spread application of kyphoplasty may be mainly due to reducing the complication rates associated with cement leakage and possible restoration, even though partially, of a vertebral kyphotic deformity. MATERIALS AND

METHODS:

we experienced three cases of newly emerged complications that caused delayed neurologic compromise after uneventful kyphoplasty without any immediate neurologic deficits. MR imaging was done to find the pathologic regions and surgical treatment was performed.

RESULTS:

Refracture of an augmented vertebra at the conus medullaris level can cause late occurring spinal cord compression without compromising the spinal canal. Posterior instrumentation and posterior fusion with posterior decompression were effective treatments.

CONCLUSION:

The anatomical peculiarity of the conus medullaris and the dynamic irritation of the spinal cord by a bone cement mass after refracture of an augmented vertebral body can be the causes of late spinal cord compression after kyphoplasty. The neurologic symptoms were treated by posterior decompression and fusion. This kind of complication can be prevented by injecting a sufficient amount of bone cement with a shape to support both endplates.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Canal Medular / Medula Espinal / Compressão da Medula Espinal / Coluna Vertebral / Anormalidades Congênitas / Descompressão / Caramujo Conus / Fraturas por Compressão / Cifoplastia / Manifestações Neurológicas Idioma: Coreano Revista: Journal of Korean Society of Spine Surgery Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Canal Medular / Medula Espinal / Compressão da Medula Espinal / Coluna Vertebral / Anormalidades Congênitas / Descompressão / Caramujo Conus / Fraturas por Compressão / Cifoplastia / Manifestações Neurológicas Idioma: Coreano Revista: Journal of Korean Society of Spine Surgery Ano de publicação: 2010 Tipo de documento: Artigo