Your browser doesn't support javascript.
loading
Unenhanced Breast MRI With Diffusion-Weighted Imaging for Breast Cancer Detection: Effects of Training on Performance and Agreement of Subspecialty Radiologists
Korean Journal of Radiology ; : 11-23, 2024.
Artigo em Inglês | WPRIM | ID: wpr-1044840
ABSTRACT
Objective@#To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). @*Materials and Methods@#A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm 2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive.The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). @*Results@#Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI] 59.4–79.9), 90.8% (95% CI 85.6–94.2), and 83.5% (95% CI 78.6–87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI 90.8–97.5; P = 0.001) and accuracy (85.9%; 95% CI 80.9–89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI 58.1–79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI 0.52–0.63) before training and 0.68 (95% CI 0.62–0.74) after training, with a difference of 0.11 (95% CI 0.02–0.18; P = 0.01). The ICC was 0.73 (95% CI 0.69–0.74) before training and 0.79 (95% CI 0.76–0.80) after training (P = 0.002). @*Conclusion@#Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2024 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2024 Tipo de documento: Artigo