A Case of Near Total Occlusion of the Renal Artery after Endovascular Abdominal Aortic Aneurysm Repair
Journal of Lipid and Atherosclerosis
;
: 45-49, 2015.
Artigo
em Inglês
| WPRIM
| ID: wpr-104677
ABSTRACT
Endovascular abdominal aortic aneurysm repair is a safe, durable, and effective procedure. However, complications could occur with stent graft devices. When the renal ostia become obstructed by this device, renovascular hypertension may result. In general, renal artery occlusion secondary to stent graft impingement remains uncommon. We herein describe a patient with renal atrophy, new-onset hypertension, and elevated serum renin and aldosterone levels following endovascular aneurysm repair. Blood pressure and the levels of renin and aldosterone were normalized by renal artery stenting.