Your browser doesn't support javascript.
loading
Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography
Restorative Dentistry & Endodontics ; : 58-67, 2015.
Artigo em Inglês | WPRIM | ID: wpr-105468
ABSTRACT

OBJECTIVES:

This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. MATERIALS AND

METHODS:

Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test.

RESULTS:

The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed.

CONCLUSIONS:

If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Dente / Radiografia / Sensibilidade e Especificidade / Diagnóstico / Tomografia Computadorizada de Feixe Cônico / Tomografia Computadorizada Multidetectores / Dente Molar Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Restorative Dentistry & Endodontics Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Dente / Radiografia / Sensibilidade e Especificidade / Diagnóstico / Tomografia Computadorizada de Feixe Cônico / Tomografia Computadorizada Multidetectores / Dente Molar Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Restorative Dentistry & Endodontics Ano de publicação: 2015 Tipo de documento: Artigo