The Number of Removed Lymph Nodes for an Acceptable False Negative Rate in Sentinel Lymph Node Biopsy for Breast Cancer / 한국유방암학회지
Journal of Breast Cancer
;
: 100-105, 2009.
Artigo
em Coreano
| WPRIM
| ID: wpr-106935
ABSTRACT
PURPOSE:
This study was performed to find the adequate number of removed lymph nodes to achieve an acceptable false-negative rate when performing sentinel lymph node biopsy for breast cancer.METHODS:
A total of 179 sentinel node biopsies combined with conventional axillary lymph node dissection for breast cancer were performed between November 2003 and June 2007.RESULTS:
The overall identification rate of sentinel lymph node and the false negative rate of the biopsy were 95.0% and 8.1%, respectively. Yet the false negative rate of the biopsy was lowered as the number of the removed nodes was increased. Especially, the false negative rate was 0% when more than 4 lymph nodes were removed.CONCLUSION:
We recommend that four lymph nodes should be removed to obtain accurate results in sentinel node biopsy for breast cancer.