Acute Closure of Target and Remote Coronary Arteries Complicated by Balloon Rupture during Primary Stenting of Acute Myocardial Infarction
Korean Circulation Journal ; : 424-428, 1999.
Artigo em Coreano | WPRIM | ID: wpr-107105
ABSTRACT
Primary coronary stenting is one of the established therapeutic options for acute myocardial infarction. The risk of balloon rupture during stenting may be increased after high pressure inflation technique was introduced. Balloon rupture during stenting may cause catastrophic complications such as extensive dissection, acute closure, coronary perforation. We report a case of balloon rupture during primary stenting in acute myocardial infarction, which caused acute thrombotic closure of target and remote coronary arteries simultaneously.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Ruptura / Stents / Vasos Coronários / Inflação / Infarto do Miocárdio Idioma: Coreano Revista: Korean Circulation Journal Ano de publicação: 1999 Tipo de documento: Artigo