ABSTRACT

PURPOSE:

To introduce and assess the results of punctoplasty using a radiofrequency surgical unit for punctal stenosis.

METHODS:

Patients who complained of epiphora, had an intact lacrimal pathway below puncti, and underwent punctoplasty with the Ellman Surgitron F.F.P.F were evaluated in the present study.

RESULTS:

A total of 19 patients (31 eyes) were included in the study. The average age was 55 years (+/-15.7 years). At the last follow-up visit, 27 eyes (87%) had patent puncti, 1 eye became stenotic again, and 3 eyes were completely obstructed. Twenty-two eyes (71%) showed almost complete disappearance of dye on the fluorescein dye-disappearance test (FDDT). Twenty-five eyes (81%) had symptomatic improvement. No significant complication was reported postoperatively.

CONCLUSIONS:

Punctoplasty with a radiofrequency surgical unit is a simple and effective method for punctal stenosis.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Seguimentos / Constrição Patológica / Fluoresceína / Olho / Doenças do Aparelho Lacrimal Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2012 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Seguimentos / Constrição Patológica / Fluoresceína / Olho / Doenças do Aparelho Lacrimal Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2012 Tipo de documento: Artigo