ABSTRACT
Electrocardiogram-gated single photon emission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Perfusão / Doença da Artéria Coronariana / Imageamento por Ressonância Magnética / Ecocardiografia / Tomografia Computadorizada de Emissão de Fóton Único / Ventriculografia de Primeira Passagem / Função Ventricular / Tecnécio / Fótons Limite: Humanos Idioma: Coreano Revista: Korean Journal of Nuclear Medicine Ano de publicação: 2005 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Perfusão / Doença da Artéria Coronariana / Imageamento por Ressonância Magnética / Ecocardiografia / Tomografia Computadorizada de Emissão de Fóton Único / Ventriculografia de Primeira Passagem / Função Ventricular / Tecnécio / Fótons Limite: Humanos Idioma: Coreano Revista: Korean Journal of Nuclear Medicine Ano de publicação: 2005 Tipo de documento: Artigo