Experience of Urethral Replacement with Gore-Tex(Polytetrafluoroethylene) Graft for a Difficult Urethral Strictures: l case / 대한비뇨기과학회지
Korean Journal of Urology
;
: 731-734, 1987.
Artigo
em Coreano
| WPRIM
| ID: wpr-113315
ABSTRACT
In a 73 year old male patient with multiple urethral strictures, we performed urethral replacement with Gore-Tex(Polytetrafluoroethylene) graft about l0cm long. On a follow up, 5 months later, operative field was reexplored due to pains and we found that urethral regeneration was complete around the Gore-Tex graft while the graft itself was remaining inside the urethral lumen in a freely detached state. After the removal of Core- Tex graft, patient could void in a normal fashion quite satisfactory. We think that urethral replacement graft with Gore-Tex should be given a consideration as a last resort.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Politetrafluoretileno
/
Regeneração
/
Estreitamento Uretral
/
Seguimentos
/
Transplantes
/
Estâncias para Tratamento de Saúde
Tipo de estudo:
Estudo observacional
/
Estudo prognóstico
Limite:
Idoso
/
Humanos
/
Masculino
Idioma:
Coreano
Revista:
Korean Journal of Urology
Ano de publicação:
1987
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS