ABSTRACT

PURPOSE:

To evaluate the accuracy of various formulas installed in IOLMaster software which uses partial coherence interferometry for axial length measurement.

METHODS:

This retrospective comparative study included 81 eyes of consecutive patients who had uneventful cataract surgery with implantation of Acrysof single piece (SA60AT) IOL. Axial length was measured with IOLMaster and IOL power was calculated using various formulas, including SRK II, SRK/T, Holladay 1, Haigis, and Hoffer Q. Subjects were stratified by axial length into Groups A (axial length or = 25.00 mm). Target refractions of the five formulas were compared to the postoperative manifest refraction at 1 month.

RESULTS:

The five formulas showed no difference in predicting postoperative refractive errors among all of the groups.

CONCLUSIONS:

Five formulas installed in IOLMaster software provided equivalent predictions of postoperative refractive error regardless of axial length.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Erros de Refração / Catarata / Estudos Retrospectivos / Olho / Interferometria / Lentes Intraoculares Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Erros de Refração / Catarata / Estudos Retrospectivos / Olho / Interferometria / Lentes Intraoculares Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2009 Tipo de documento: Artigo