Your browser doesn't support javascript.
loading
The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients / 대한마취과학회지
Article em En | WPRIM | ID: wpr-11894
Biblioteca responsável: WPRO
ABSTRACT
BACKGROUND: The usefulness of dynamic parameters derived by heart-lung interaction for fluid responsiveness in pediatric patients has been revealed. However, the effects of peak inspiratory pressure (PIP) that could affect the absolute values and the accuracy in pediatric patients have not been well established. METHODS: Participants were 30 pediatric patients who underwent ventricular septal defect repair. After completion of surgical procedure and sternum closure, mean arterial blood pressure, heart rate, central venous pressure, cardiac output, cardiac index and stroke volume variation (SVV) were measured at PIP 10 cmH2O (PIP10), at PIP 15 cmH2O (PIP15), at PIP 20 cmH2O (PIP20) and at PIP 25 cmH2O (PIP25). RESULTS: SVV at PIP15 was larger than that at PIP10 (13.7 +/- 2.9% at PIP10 vs 14.7 +/- 2.5% at PIP15, P < 0.001) and SVV at PIP20 was larger than that at PIP10 and PIP15 (13.7 +/- 2.9% at PIP10 vs 15.4 +/- 2.5% at PIP20, P < 0.001; 14.7 +/- 2.5% at PIP15 vs 15.4 +/- 2.5% at PIP20, P < 0.001) and SVV at PIP25 was larger than that at PIP10 and PIP15 and PIP20 (13.7 +/- 2.9% at PIP10 vs 17.4 +/- 2.4% at PIP25, P < 0.001; 14.7 +/- 2.5% at PIP15 vs 17.4 +/- 2.4% at PIP25, P < 0.001; 15.4 +/- 2.5% at PIP20 vs 17.4 +/- 2.4% at PIP25, P < 0.001). CONCLUSIONS: SVV is affected by different levels of PIP in same patient and under same volume status. This finding must be taken into consideration when SVV is used to predict fluid responsiveness in mechanically ventilated pediatric patients.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Esterno / Volume Sistólico / Cirurgia Torácica / Ventilação / Débito Cardíaco / Ventiladores Mecânicos / Pressão Venosa Central / Pressão Arterial / Hidratação / Frequência Cardíaca Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Korean Journal of Anesthesiology Ano de publicação: 2014 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Esterno / Volume Sistólico / Cirurgia Torácica / Ventilação / Débito Cardíaco / Ventiladores Mecânicos / Pressão Venosa Central / Pressão Arterial / Hidratação / Frequência Cardíaca Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Korean Journal of Anesthesiology Ano de publicação: 2014 Tipo de documento: Article