Your browser doesn't support javascript.
loading
Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 576-582, 2003.
Artigo em Coreano | WPRIM | ID: wpr-120314
ABSTRACT

BACKGROUND:

During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. MATERIAL AND

METHOD:

From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71. The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin I and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay.

RESULT:

The number of mean distal anastomoses was 2.8+/-0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2+/-46.7 for CK-MB, 0.69+/-0.86 for troponin I on postoperative day 1. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed.

CONCLUSION:

The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic change of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Artéria Pulmonar / Pressão Sanguínea / Ventiladores Mecânicos / Tubos Torácicos / Drenagem / Ponte de Artéria Coronária / Troponina I / Transplantes / Eletrocardiografia Limite: Humanos Idioma: Coreano Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2003 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Artéria Pulmonar / Pressão Sanguínea / Ventiladores Mecânicos / Tubos Torácicos / Drenagem / Ponte de Artéria Coronária / Troponina I / Transplantes / Eletrocardiografia Limite: Humanos Idioma: Coreano Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2003 Tipo de documento: Artigo