Postoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted in Cataract Surgery
Korean Journal of Ophthalmology
;
: 22-28, 2011.
Artigo
em Inglês
| WPRIM
| ID: wpr-121942
ABSTRACT
PURPOSE:
This study was conducted to compare post-operative astigmatic outcomes of two groups, with-the-rule (WTR) and against-the-rule (ATR) astigmatism patients, according to the haptic axis of intraocular lenses (IOLs) inserted in cataract surgery.METHODS:
Seventy-two eyes with WTR astigmatism and 79 eyes with ATR astigmatism had cataract surgery through a clear corneal temporal incision. These two groups of eyes were then each divided into 2 groups based on whether the haptic axis of the inserted IOL was at 180degrees or 90degrees. For ATR patients, the outcomes were analyzed according to the three types of IOLs.RESULTS:
There was no difference in corneal astigmatism, but WTR patients with a 180degrees haptic axis of the inserted IOL and ATR patients with a 90degrees hepatic axis of the inserted IOL had a significant decrease in postoperative refractive astigmatism (p < 0.05). The changes in ATR astigmatism according to the IOL type were more effective in single-piece acrylic IOLs than in the three-piece polymethylmethacrylate haptic IOL group.CONCLUSIONS:
Insertion of the IOL at the 180degrees haptic axis in WTR patients and at 90degrees in ATR patients during cataract surgery may have an effect in reducing pre-existing astigmatism. This observed effect was not consistent among the different types of IOLs.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Complicações Pós-Operatórias
/
Astigmatismo
/
Extração de Catarata
/
Resultado do Tratamento
/
Implante de Lente Intraocular
/
Desenho de Equipamento
/
Lentes Intraoculares
Limite:
Humanos
Idioma:
Inglês
Revista:
Korean Journal of Ophthalmology
Ano de publicação:
2011
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS