Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model / 대한구강악안면방사선학회지
Korean Journal of Oral and Maxillofacial Radiology ; : 27-33, 2002.
Artigo em Coreano | WPRIM | ID: wpr-125567
ABSTRACT

PURPOSE:

To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model MATERIAL AND

METHODS:

CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works(TM) 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated.

RESULTS:

There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm(2.52%) between linear measurements of dry skull and 800 RP model.

CONCLUSION:

Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Crânio / Processamento de Imagem Assistida por Computador / Microcomputadores / Discos Compactos / Imageamento Tridimensional Limite: Humanos Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Ano de publicação: 2002 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Crânio / Processamento de Imagem Assistida por Computador / Microcomputadores / Discos Compactos / Imageamento Tridimensional Limite: Humanos Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Ano de publicação: 2002 Tipo de documento: Artigo