Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta
The Korean Journal of Thoracic and Cardiovascular Surgery
;
: 212-215, 2013.
Artigo
em Inglês
| WPRIM
| ID: wpr-129690
ABSTRACT
A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Aorta
/
Valva Aórtica
/
Tórax
/
Dor no Peito
/
Ecocardiografia
/
Constrição
/
Dispneia
/
Catéteres
/
Ventrículos do Coração
Limite:
Humanos
Idioma:
Inglês
Revista:
The Korean Journal of Thoracic and Cardiovascular Surgery
Ano de publicação:
2013
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS