Ideal Right Ventricular Outflow Tract Size in Tetralogy of Fallot Total Correction / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 588-597, 2006.
Artigo em Coreano | WPRIM | ID: wpr-134289
ABSTRACT

BACKGROUND:

The surgical repair of a tetralogy of Fallot (TOF) has been performed successfully with a favorable early and late outcome. However, the later development of pulmonary regurgitation and stenosis remains a problem. The development of pulmonary regurgitation and stenosis may be changed by the size of right ventricular outflow tract (RVOT) reconstruction at the initial total correction. Hence, it is necessary to investigate the ideal size of RVOT reconstruction. MATERIAL AND

METHOD:

This prospective study was carried out to determine how a surgical strategy and the RVOT size affect the occurrence of pulmonary regurgitation and stenosis. From January 2002 to December 2004, 62 patients underwent the TOF total correction. The RVOT size (diameter of pulmonary valve annulus) of each case was measured after the RVOT reconstruction and converted to a Z value. A pre-scheduled follow up (at discharge, 6 months, 1 year, 2 years and 3 years) was carried out by echocardiography to evaluate the level of pulmonary regurgitation and stenosis.

RESULT:

The patients were divided to two groups (transannular group n=12, nontransannular group n=50) according to the method of a RVOT reconstruction. The Z value of RVOT=iameter of pulmonary valve annulus) (transannular group -1, range -3.6~-0.8; nontransannular group -2.1, range -5.2~1.5) and the average pRV/LV after surgery (transannular group 0.44+/-0.09, nontransannular group 0.42+/-0.09) did not show any significant difference between two groups. The occurrence of pulmonary regurgitation above a moderate degree was more frequent in the transannular group (p0, p<0.02) and the progressing pulmonary stenosis more than mild to moderate degree developed in the patients with smaller RVOT size (Z value<-1.5, p<0.05). A moderate degree of pulmonary stenosis developed for 4 nontransannular patients. Three underwent additional surgery and one underwent a balloon valvuloplasty. Their Z value of RVOT were -3.8, -3.8 -2.9, -1.8, respectively.

CONCLUSION:

When carring out a TOF total correction, transannular RVOT reconstruction group has significantly more pulmonary regurgitation. In the nontransannular RVOT reconstruction, the size of the RVOT should be maintained from Z value -1.5 to 0. If the Z value is less than -1.5, we should follow up carefully for the possibility of pulmonary stenosis.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valva Pulmonar / Insuficiência da Valva Pulmonar / Estenose da Valva Pulmonar / Tetralogia de Fallot / Ecocardiografia / Estudos Prospectivos / Seguimentos / Constrição Patológica / Valvuloplastia com Balão Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Coreano Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2006 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valva Pulmonar / Insuficiência da Valva Pulmonar / Estenose da Valva Pulmonar / Tetralogia de Fallot / Ecocardiografia / Estudos Prospectivos / Seguimentos / Constrição Patológica / Valvuloplastia com Balão Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Coreano Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2006 Tipo de documento: Artigo