Successful use of C-MAC® video laryngoscope following failure of multiple intubation attempts during laryngomicroscopic surgery in an infant: A case report
Anesthesia and Pain Medicine
;
: 339-341, 2017.
Artigo
em Inglês
| WPRIM
| ID: wpr-136438
ABSTRACT
A 6-month-old boy was scheduled for a laryngeal mass excision and tracheal bougienage for secondary subglottic stenosis. Following successful excision of the laryngeal mass, a tracheal tube was temporarily extubated for tracheal bougination. However, tracheal re-intubation using a direct laryngoscope with the Miller blade failed because of mucosal swelling and bloody secretions. Following multiple intubation attempts, the patient's peripheral oxygen saturation had decreased to 52%. Immediately, a video laryngoscope was requested, and, by using the C-MAC® video laryngoscope, the patient was successfully re-intubated. Because pediatric patients are more vulnerable to desaturation, extreme caution should be used in securing airways even during a short apneic period. Using a video laryngoscope at the first intubation attempt would be useful for successful tracheal intubation.