Your browser doesn't support javascript.
loading
Study of Acute Myelocytic Leukemia Patient Treatment That Used Total Skin Electron Beam / 의학물리
Korean Journal of Medical Physics ; : 152-158, 2009.
Artigo em Coreano | WPRIM | ID: wpr-137641
ABSTRACT
Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is 60 degrees around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aceleradores de Partículas / Porfirinas / Pele / Dosimetria Termoluminescente / Tórax / Leucemia Mieloide Aguda / Leucemia Mieloide / Micose Fungoide / Eletrônica / Elétrons Limite: Humanos Idioma: Coreano Revista: Korean Journal of Medical Physics Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aceleradores de Partículas / Porfirinas / Pele / Dosimetria Termoluminescente / Tórax / Leucemia Mieloide Aguda / Leucemia Mieloide / Micose Fungoide / Eletrônica / Elétrons Limite: Humanos Idioma: Coreano Revista: Korean Journal of Medical Physics Ano de publicação: 2009 Tipo de documento: Artigo