New Technique for Removal of the Ulnar Intramedullary Nail Failed to Remove: Broken Assembly Piece in the Nail
Clinics in Orthopedic Surgery ; : 210-213, 2016.
Artigo em Inglês | WPRIM | ID: wpr-138569
ABSTRACT
Methods about removal of intramedullary nail in complicated cases were reported in some literatures but there are no reports about nail removal in the ulna. The authors would like to report such a case and the technique. We removed bone of the inlet site and created another bony window using an osteotome to expose the interlocking screw holes. Only a bony window the size of 2 inter-interlocking holes at the most proximal part of the nail can be used to remove the nail with minimal damage of the triceps brachii tendon and soft tissue.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Tendões / Ulna / Baías / Remoção de Dispositivo / Fixação Intramedular de Fraturas Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2016 Tipo de documento: Artigo