Comparison of Cytologic Evaluation between Conventional Method and CellprepPlus(R) Liquid-Based Cytology in Body Fluid
Korean Journal of Pathology
;
: 448-452, 2009.
Artigo
em Coreano
| WPRIM
| ID: wpr-14783
ABSTRACT
BACKGROUND:
Assessment of body fluid cytology is a useful means of evaluating a metastatic tumor. Liquid-based cytology (LBC) has been developed as a replacement for the conventional Papanicolaou (CP) test. This study was performed to compare CellprepPlus(R) LBC with CP in cytologic diagnosis.METHODS:
Body fluid samples (n=188, including 72 peritoneal fluid and 116 pleural fluid samples) were divided equally and analyzed by both CellprepPlus(R) and CP.RESULTS:
CellprepPlus(R) revealed distributed thin layers of non-overlapping cells. All CellprepPlus(R) preparations were adequate, while 18 (9.57%) CP preparations were inadequate. The respective diagnostic rates of CellprepPlus(R) and CP were 75.0% and 76.1% negative, 10.6% and 6.38% atypical, 5.85% and 2.66% suspicious, and 8.51% and 5.32% malignant. Of the 58 confirmed cases, the sensitivity of CellprepPlus(R) and CP was 94.4% and 73.3%, respectively, and the negative predictive value was 97.2% and 87.9%, respectively.CONCLUSIONS:
CellprepPlus(R) LBC has better sensitivity and negative predictive value, and produces higher quality slide preparations than than CP, making it suitable as in screening of body fluid as a cytologic diagnostic tool.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Líquidos Corporais
/
Líquido Ascítico
/
Programas de Rastreamento
/
Metástase Neoplásica
Tipo de estudo:
Estudo de rastreamento
Idioma:
Coreano
Revista:
Korean Journal of Pathology
Ano de publicação:
2009
Tipo de documento: