Your browser doesn't support javascript.
loading
Fetal Echocardiographic Measurements of Aortic Arch between 20 and 38 Gestational Weeks: Normative Data for Various Fetal Growth Parameters / 대한주산의학회잡지
Korean Journal of Perinatology ; : 201-208, 2011.
Artigo em Coreano | WPRIM | ID: wpr-148036
ABSTRACT

PURPOSE:

Assessment of the diameters of the aortic arches in the human fetus may be helpful in the prenatal diagnosis of aortic arch anomalies. The purpose of this study is to construct valuable reference ranges of fetal aortic arch for various fetal growth parameters in an unselected Korean population.

METHODS:

A prospective, cross-sectional study was performed in 98 normal singleton fetuses between 20 and 38 weeks of gestation. The transverse aortic arch diameter (TAD) and distal aorta isthmus diameter (AID) were measured in the longitudinal view during systole. The bi-parietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL) were obtained at the same time. Ultrasound examinations were performed with a 2.0-6.0 MHz convex probe by abdominal ultrasound.

RESULTS:

TAD and AID as a function of gestational age (GA) was expressed by the regression equation TAD= -1.246+0.168 X GA, and AID = -1.341+0.180 X GA; TAD and AID are expressed in millimeters and GA in weeks. TAD and AID as a function of BPD was expressed by the regression equation TAD= -1.147+0.664 X BPD, and AID = -1.152+0.696 X BPD. TAD and AID as a function of HC was expressed by the regression equation TAD = -1.187+0.182 X HC, and AID = -1.350+0.198 X HC. TAD and AID as a function of AC was expressed by the regression equation TAD = -0.528+0.173 X AC, and AID = -0.533+0.183 X AC. TAD and AID as a function of FL was expressed by the regression equation TAD = -0.519+0.799 X FL, and AID = -0.601+0.860 X FL; BPD, HC, AC and FL are expressed in centimeters. Correlations were found to be highly statistically significant in relation to GA, BPD, HC, AC, and FL respectively (P<0.0001 in all). Normal mean of TAD and AID per GA, BPD, HC, AC and FL and 95% prediction limits were also defined, respectively.

CONCLUSION:

New reference ranges of fetal aortic arch related to other fetal bio-parameters representing fetal growth were obtained successfully. The normative date will be helpful in the prenatal accurate diagnosis of aortic anomalies and abnormal growth of fetal aortic arches in Korea.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aorta / Aorta Torácica / Diagnóstico Pré-Natal / Valores de Referência / Sístole / Ecocardiografia / Estudos Transversais / Estudos Prospectivos / Idade Gestacional / Desenvolvimento Fetal Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Humanos / Gravidez País/Região como assunto: Ásia Idioma: Coreano Revista: Korean Journal of Perinatology Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aorta / Aorta Torácica / Diagnóstico Pré-Natal / Valores de Referência / Sístole / Ecocardiografia / Estudos Transversais / Estudos Prospectivos / Idade Gestacional / Desenvolvimento Fetal Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Humanos / Gravidez País/Região como assunto: Ásia Idioma: Coreano Revista: Korean Journal of Perinatology Ano de publicação: 2011 Tipo de documento: Artigo