Your browser doesn't support javascript.
loading
Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area / 대한구강악안면방사선학회지
Article em Ko | WPRIM | ID: wpr-15100
Biblioteca responsável: WPRO
ABSTRACT
PURPOSE: The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. MATERIALS AND METHODS: Five partially edentulous dry human mandibles, with 1x1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographies were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0(R) (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. RESULTS: There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). CONCLUSION: Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Microcomputadores / Implantes Dentários / Tomografia Computadorizada de Feixe Cônico / Guta-Percha / Mandíbula Limite: Humans Idioma: Ko Revista: Korean Journal of Oral and Maxillofacial Radiology Ano de publicação: 2009 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Microcomputadores / Implantes Dentários / Tomografia Computadorizada de Feixe Cônico / Guta-Percha / Mandíbula Limite: Humans Idioma: Ko Revista: Korean Journal of Oral and Maxillofacial Radiology Ano de publicação: 2009 Tipo de documento: Article