ABSTRACT

PURPOSE:

The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool children.

METHODS:

A total of 133 healthy Korean preschool children were selected from 639 children (aged 3 to 6 years) who attended kindergarten in Seongnam, Gyeonggi province, Korea. Healthy children were defined according to the European Respiratory Society (ERS) criteria. All subjects underwent lung function tests using IOS. The relationships between IOS value (respiratory resistance (Rrs) and reactance (Xrs) at 5 and 10 Hz and resonance frequency (RF)) and age, height, and weight were analyzed by simple linear and multiple linear regression analyses.

RESULTS:

The IOS success rate was 89.5%, yielding data on 119 children. Linear regression identified height as the best predictor of Rrs and Xrs. Using stepwise multiple linear regressions based on age, height, and weight, we determined regression equations and coefficients of determination (R2) for boys (Rrs5=1.934-0.009xHeight, R2=12.1%; Xrs5=0.774+0.006xHeight-0.002xAge, R2=20.2% and for girls (Rrs5=2.201-0.012xHeight, R2=18.2%; Xrs5=-0.674+0.004xHeight, R2=10.5%).

CONCLUSION:

This study provides reference values for IOS measurements of normal Korean preschool children. These provide a basis for the diagnosis and monitoring of preschool children with a variety of respiratory diseases.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oscilometria / Valores de Referência / Testes de Função Respiratória / Sistema Respiratório / Modelos Lineares / Resistência das Vias Respiratórias / Impedância Elétrica / Coreia (Geográfico) / Pulmão / Medidas de Volume Pulmonar Tipo de estudo: Estudo prognóstico Limite: Criança / Criança, pré-escolar / Humanos País/Região como assunto: Ásia Idioma: Inglês Revista: Korean Journal of Pediatrics Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oscilometria / Valores de Referência / Testes de Função Respiratória / Sistema Respiratório / Modelos Lineares / Resistência das Vias Respiratórias / Impedância Elétrica / Coreia (Geográfico) / Pulmão / Medidas de Volume Pulmonar Tipo de estudo: Estudo prognóstico Limite: Criança / Criança, pré-escolar / Humanos País/Região como assunto: Ásia Idioma: Inglês Revista: Korean Journal of Pediatrics Ano de publicação: 2011 Tipo de documento: Artigo