Your browser doesn't support javascript.
loading
A 15-year clinical retrospective study of Branemark implants / 대한치과보철학회지
The Journal of Korean Academy of Prosthodontics ; : 61-66, 2012.
Artigo em Coreano | WPRIM | ID: wpr-155667
ABSTRACT

PURPOSE:

This study was to compare the cumulative survival rate (CSR) of Branemark machined surface implants and TiUnite(TM) imlants and to analyze association between risk factors and the CSR of the implants. MATERIALS AND

METHODS:

A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Branemark machined and TiUnite(TM) implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite(TM) implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (alpha=.05).

RESULTS:

Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Branemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite(TM) implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Branemark and Nobel Biocare TiUnite(TM) during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite(TM) implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification.

CONCLUSION:

Clinical performance of Branemark machined and TiUnite(TM) implant demonstrated a high level of predictability. In this study, TiUnite(TM) implant was more successful than machined implant. The implant CSR was associated with several risk factors.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próteses e Implantes / Contenções / Dente / Implantes Dentários / Registros Odontológicos / Taxa de Sobrevida / Estudos Retrospectivos / Fatores de Risco / Seguimentos / Tábuas de Vida Tipo de estudo: Estudo de etiologia / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino País/Região como assunto: Ásia Idioma: Coreano Revista: The Journal of Korean Academy of Prosthodontics Ano de publicação: 2012 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próteses e Implantes / Contenções / Dente / Implantes Dentários / Registros Odontológicos / Taxa de Sobrevida / Estudos Retrospectivos / Fatores de Risco / Seguimentos / Tábuas de Vida Tipo de estudo: Estudo de etiologia / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino País/Região como assunto: Ásia Idioma: Coreano Revista: The Journal of Korean Academy of Prosthodontics Ano de publicação: 2012 Tipo de documento: Artigo