Your browser doesn't support javascript.
loading
Wire-reinforced endotracheal tube fire during tracheostomy: A case report / 대한마취과학회지
Korean Journal of Anesthesiology ; : 157-160, 2012.
Artigo em Inglês | WPRIM | ID: wpr-156170
ABSTRACT
Every operation could have a fire emergency, especially in the case of a tracheostomy. When a flammable gas meets a source of heat, the danger of fire is remarkable. A tracheal tube filled with a high concentration of oxygen is also a great risk factor for fire. Intra-tracheal tube fire is a rare, yet critical emergency with catastrophic consequences. Thus, numerous precautions are taken during a tracheostomy like, use of a special tube to prevent laser damage, ballooning of the tube with normal saline instead of air, and dilution of FiO2 with helium or nitrogen. Since the first recorded cases on tube fires, most of the fires were initiated in the balloon and the tip. In the present case report, however, we came across a fire incidence, which originated from the wire.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Porfirinas / Queimaduras / Traqueostomia / Incidência / Fatores de Risco / Emergências / Manuseio das Vias Aéreas / Incêndios / Temperatura Alta Tipo de estudo: Estudo de etiologia / Estudo de incidência / Estudo prognóstico / Fatores de risco Idioma: Inglês Revista: Korean Journal of Anesthesiology Ano de publicação: 2012 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Porfirinas / Queimaduras / Traqueostomia / Incidência / Fatores de Risco / Emergências / Manuseio das Vias Aéreas / Incêndios / Temperatura Alta Tipo de estudo: Estudo de etiologia / Estudo de incidência / Estudo prognóstico / Fatores de risco Idioma: Inglês Revista: Korean Journal of Anesthesiology Ano de publicação: 2012 Tipo de documento: Artigo