Jugular Bulb Venous Oxygen Saturation Monitoring in Brain Surgery / 대한마취과학회지
Korean Journal of Anesthesiology
;
: 599-605, 2001.
Artigo
em Coreano
| WPRIM
| ID: wpr-156331
ABSTRACT
BACKGROUND:
During intracranial brain surgery, numerous factors may alter cerebral blood flow and the oxygen supply-demend balance. Continuous monitoring of the jugular bulb venous oxygen saturation (SjvO2) may help in the anesthetic management of such procedures.METHODS:
Fiberoptic SjvO2 was continuously monitored and recorded 1, 3 and 5 min after the skin incision, skull bone craniotomy, dura open and dura closure in 20 patients.RESULTS:
The SjvO2 was increased after the skin (scalp) incision at 1, 3 and 5 minutes and also after endotracheal suctioning for removal of secretions.CONCLUSIONS:
Although the accuracy of Fibroptic SjvO2 determination is limited, it allows the detection of cerebral blood flow and oxygen supply-demend imbalance during brain surgery. The frequent occurance of SjvO2 elevations is suggestive of reactive hyperemia mechaniams.