Evaluation of Quality of Intraoperative Salvaged Red Blood Cells Processed by CATS(Plus) / 대한수혈학회지
Korean Journal of Blood Transfusion
;
: 113-119, 2009.
Artigo
em Coreano
| WPRIM
| ID: wpr-160019
ABSTRACT
BACKGROUND:
CATS(Plus) (continuous autotransfusion system, Fresenius Kabi, Friedberg, Germany) is a continuous, chamber type cell salvage system for performing an intraoperative autologous transfusion. We evaluated the quality of intraoperative salvaged red blood cells processed by CATS(Plus).METHODS:
A total 20 adult patients undergone lumbar spine surgery were enrolled in this study. Laboratory tests including albumin, potassium, free hemoglobin, and bacterial culture were performed and the % albumin removal was calculated.RESULTS:
The average albumin, potassium, and free hemoglobin concentration were 4 g/L, 4.86 mEq/L, 4.50 g/L, respectively. Mean albumin removal was 87%. Bacterial culture was positive in 11 of the 20 cases and staphylococcus species were isolated in all of the culture positive cases.CONCLUSION:
For safe use of salvaged red blood cells, laboratory tests for potassium and free hemoglobin concentration would be necessary before administration.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Potássio
/
Coluna Vertebral
/
Staphylococcus
/
Transfusão de Sangue Autóloga
/
Hemoglobinas
/
Eritrócitos
/
Hemólise
Limite:
Adulto
/
Humanos
Idioma:
Coreano
Revista:
Korean Journal of Blood Transfusion
Ano de publicação:
2009
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS