Your browser doesn't support javascript.
loading
The Predictive Values of Various Parameters in the Diagnosis of Stress Urinary Incontinence
Yonsei Medical Journal ; : 287-292, 2004.
Artigo em Inglês | WPRIM | ID: wpr-162564
ABSTRACT
The Maximum Urethral Closure Pressure (MUCP) and Functional Urethral Length (FUL) are significant parameters of the Urethral Pressure Profile (UPP), while the Q-tip angle and Bladder Neck Descent (BND) are the significant parameters of urethral hypermobility. We performed a study to evaluate the effects and predictive values of each of these parameters in the diagnosis of Stress Urinary Incontinence (SUI). A retrospective study was done involving 90 SUI patients and 38 non-SUI patients who underwent urodynamic study, Q-tip test and perineal ultrasound at Yonsei Medical Center between January, 1999 and February, 2002. There was no statistical difference between the SUI and non-SUI groups in terms of mean age, delivery history, menopausal age and body mass index. While the FUL and Q-tip angle showed significant differences (33.18 +/- 19.55 vs 33.12 +/- 13.37 mm, p=0.002; 65.94 +/- 21.69 vs 56.45 +/- 26.53 degrees, p=0.02, respectively) neither the MUCP nor the BND showed any significant difference between the two groups (60.06 +/- 29.92 vs 48.97 +/- 42.95 cmH2O, p > 0.05; 1.09 +/- 0.75 vs 0.85 +/- 0.76 cm, p > 0.05; 0.71 +/- 0.80 vs 0.53 +/- 0.72 cm, p > 0.05). The odds ratios for the FUL and Q-tip angle were 1.038 (1.014, 1.061) and 1.017 (1.001, 1.033), respectively. The FUL and Q-tip angle had cut-off values of 1.36 cm (sensitivity 68.8%, specificity 54.1%, PPV 73.8%, NPV 48.1%) and 20.47 degrees (sensitivity 93.3%, specificity 18.17%, PPV 68.2%, NPV 60%), respectively, in the diagnosis of SUI. The area under the curve (AUC) of the FUL and Q-tip angle were on average 0.625 (p=0.0016) and 0.575 (p=0.0012), respectively. Both the FUL and Q-tip angle showed a significant difference between SUI patients and the normal group. However, their value as a diagnostic tool was trivial, and since their sensitivity, specificity, positive predictive value and negative predictive value showed inconsistent results at each cut-off value, it would be difficult to apply them to clinical use. A further study is required to set-up standard diagnostic values of these variables for clinical use.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Uretra / Incontinência Urinária por Estresse / Menopausa / Valor Preditivo dos Testes / Estudos Retrospectivos / Sensibilidade e Especificidade / Fatores Etários Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2004 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Uretra / Incontinência Urinária por Estresse / Menopausa / Valor Preditivo dos Testes / Estudos Retrospectivos / Sensibilidade e Especificidade / Fatores Etários Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2004 Tipo de documento: Artigo