ABSTRACT
Surgical fires require an ignition source, oxidizer, and fuel. The pulsed dye laser (PDL) has been shown to be effective in the treatment of hypertrophic scars and keloids in dermatology. With the increasing number of applications of CO2, laser as ignition source has been associated with operating room fires in the otorhinolaryngologic field. There have been many case reports on PDL-induced fires in dermatology, but until now, there were no reports in the larynx. We describe a 57-year-old patient diagnosed with laryngeal hyperkeratosis treated by PDL-assisted laryngomicrosurgery. In this case, we experienced incidental PDL tip flaring during pulsed dye laser vaporization.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Salas Cirúrgicas / Volatilização / Cicatriz Hipertrófica / Dermatologia / Lasers de Corante / Incêndios / Queloide / Laringe / Microcirurgia Limite: Humanos Idioma: Inglês Revista: Journal of the Korean Society of Laryngology Phoniatrics and Logopedics Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Salas Cirúrgicas / Volatilização / Cicatriz Hipertrófica / Dermatologia / Lasers de Corante / Incêndios / Queloide / Laringe / Microcirurgia Limite: Humanos Idioma: Inglês Revista: Journal of the Korean Society of Laryngology Phoniatrics and Logopedics Ano de publicação: 2016 Tipo de documento: Artigo