ABSTRACT
PURPOSE:
To compare postoperative wavefront aberration and visual functions between aspherical Tecnis Z9003, a new acrylic aspheric intraocular lens (IOL), and spherical AcrySof SA60AT IOL.METHODS:
Fifty patients (56 eyes) who underwent cataract extraction and were implanted with spherical or aspherical IOLs were randomly evaluated by wavefront analysis, including an examination of spherical aberration and higher-order aberrations using two different types of aberrometers (ray tracing and automatic retinoscope), manifested refraction, a contrast sensitivity test, and modulation transfer function (MTF), three months after surgery.RESULT:
There were no statistically significant differences of spherical equivalent and best-corrected visual acuity between the two different IOL groups. However, the aspherical IOL group showed less spherical aberration and better contrast sensitivity and MTF than the spherical IOL group.CONCLUSIONS:
Tecnis Z9003 could compensate for positive spherical aberrations of the cornea and improve contrast sensitivity and MTF, thereby improving visual function.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Sensibilidades de Contraste
/
Extração de Catarata
/
Acuidade Visual
/
Córnea
/
Lentes Intraoculares
Limite:
Humanos
Idioma:
Coreano
Revista:
Journal of the Korean Ophthalmological Society
Ano de publicação:
2008
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS