Your browser doesn't support javascript.
loading
Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey
Korean Journal of Radiology ; : 1276-1282, 2015.
Artigo em Inglês | WPRIM | ID: wpr-172978
ABSTRACT

OBJECTIVE:

We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. MATERIALS AND

METHODS:

We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test.

RESULTS:

The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies.

CONCLUSION:

Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Doses de Radiação / Radiação Ionizante / Turquia / Software / Tomografia Computadorizada por Raios X / Risco / Estudos Retrospectivos / Idade Gestacional / Feto / Cabeça Tipo de estudo: Estudo diagnóstico / Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Feminino / Humanos / Gravidez País/Região como assunto: Ásia Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Doses de Radiação / Radiação Ionizante / Turquia / Software / Tomografia Computadorizada por Raios X / Risco / Estudos Retrospectivos / Idade Gestacional / Feto / Cabeça Tipo de estudo: Estudo diagnóstico / Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Feminino / Humanos / Gravidez País/Região como assunto: Ásia Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2015 Tipo de documento: Artigo