Your browser doesn't support javascript.
loading
Late Gadolinium Enhancement in Cardiac MRI in Patients with Severe Aortic Stenosis and Preserved Left Ventricular Systolic Function Is Related to Attenuated Improvement of Left Ventricular Geometry and Filling Pressure after Aortic Valve Replacement
Korean Circulation Journal ; : 312-319, 2014.
Artigo em Inglês | WPRIM | ID: wpr-175774
ABSTRACT
BACKGROUND AND

OBJECTIVES:

We investigated echocardiographic predictors left ventricular (LV) geometric changes following aortic valve replacement (AVR) according to the late gadolinium enhancement (LGE) on cardiac magnetic resonance imaging (CMR) in patients with severe aortic stenosis (AS) and preserved LV systolic function. SUBJECTS AND

METHODS:

We analyzed 41 patients (24 males, 63.1+/-8.7 years) with preserved LV systolic function who were scheduled to undergo AVR for severe AS. All patients were examined with transthoracic echocardiography (TTE), CMR before and after AVR (in the hospital) and serial TTEs (at 6 and 12 months) were repeated.

RESULTS:

The group with LGE (LGE+) showed greater wall thickness (septum, 14.3+/-2.6 mm vs. 11.5+/-2.0 mm, p=0.001, posterior; 14.3+/-2.5 mm vs. 11.4+/-1.6 mm, p<0.001), lower tissue Doppler image (TDIS', 4.4+/-1.4 cm/s vs. 5.5+/-1.2 cm/s, p=0.021; TDI E', 3.2+/-0.9 cm/s vs. 4.8+/-1.4 cm/s, p=0.002), and greater E/e' (21.8+/-10.3 vs. 15.4+/-6.3, p=0.066) than those without LGE (LGE-). Multivariate analysis show that TDI e' (odds ratio=0.078, 95% confidence interval=0.007-0.888, p=0.040) was an independent determinant of LGE+. In an analysis of the 6- and 12-month follow-up compared with pre-AVR, LGE- showed decreased LV end-diastolic diameter (48.3+/-5.0 mm vs. 45.8+/-3.6 mm, p=0.027; 48.3+/-5.0 mm vs. 46.5+/-3.4 mm, p=0.019). Moreover, E/e' (at 12 months) showed further improved LV filling pressure (16.0+/-6.6 vs. 12.3+/-4.3, p=0.001) compared with pre-AVR. However, LGE+ showed no significant improvement.

CONCLUSION:

The absence of LGE is associated with favorable improvements in LV geometry and filling pressure. TDI E' is an independent determinant of LGE in patients with severe AS and preserved LV systolic function.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Imageamento por Ressonância Magnética / Ecocardiografia / Análise Multivariada / Seguimentos / Gadolínio Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Humanos / Masculino Idioma: Inglês Revista: Korean Circulation Journal Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Imageamento por Ressonância Magnética / Ecocardiografia / Análise Multivariada / Seguimentos / Gadolínio Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Humanos / Masculino Idioma: Inglês Revista: Korean Circulation Journal Ano de publicação: 2014 Tipo de documento: Artigo