Follow-Up Assessment after Percutaneous Mitral Valvuloplasty (PMV) with Inoue Balloon
Korean Circulation Journal
;
: 1841-1851, 1998.
Artigo
em Coreano
| WPRIM
| ID: wpr-179390
ABSTRACT
BACKGROUND:
Percutaneous Mitral Valvuloplasty (PMV) is the first-line treatment modality in selected patients with symptomatic mitral stenosis and more recently available Inoue single-balloon catheter technique produces good results with low incidence of complications. The purpose of this study was to evaluate the immediate and over 6 months follow-up results after successful PMV with an Inoue balloon and to identify the predictive factors for the results.METHODS:
From May 1995 to Feburary 1997, a PMV with an Inoue balloon was tech-nically successful in 114 (95%) of the 119 patients treated at the Sejong General Hostpital. In this study, a series of echocardiographic follow-up were performed in 54 patients with rheumatic mitral stenosis, at least 6 months after their successful PMV. In PMV, the inflation was conducted in steps, starting with a recommended maximum size of balloon by the Inoue criteria. After each inflation, the mitral valve opening and competence were evaluated by Transesophageal echocardiography (TEE) and continuing increase balloon size.RESULTS:
Echocardiographic follow-up assessment was performed in 54 patients serially in a interval of 3 months or 6 months. Their mean age was 46+/-11 years (24 to 66 years) and the mean total echocardiographic score was 7.1+/-1.6. A optimal result was obtained in 95% of the cases (51/54). The post-PMV mitral valve area increased to 1.95+/-0.37 cm 2 and 1.79+/-0.28 cm 2 by 2-D and Doppler method, the average transmitral mean diastolic pressure gradient decreased to 5.16+/-2.8 mmHg and LA pressure was decreased to 11.28+/-8.2 mmHg. The newly developed and aggravated mitral regurgitation was observed in 17 patients (31.5%). The restenosis was noted in 2 cases (3.7%) after 1 year follow-up. The pre-procedural echocardiographic score for leaflet mobility, thickening and calcification was more higher in patients with restenosis. There was significant tendency of decrement in the mitral valve area in patients with a echocardiographic score=8 compared with those< or =8 over 6 months after the PMV.CONCLUSION:
PMV with the Inoue balloon under TEE guide as a combined treatment modality of patient with symptomatic mitral stenosis is relatively safe and achieves good immediate and midterm follow-up results. The echocardiographic score is considered as useful predictor of midterm results and restenosis after PMV with Inoue balloon.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Pressão Sanguínea
/
Ecocardiografia
/
Incidência
/
Seguimentos
/
Competência Mental
/
Ecocardiografia Transesofagiana
/
Catéteres
/
Inflação
/
Valva Mitral
/
Insuficiência da Valva Mitral
Tipo de estudo:
Estudo de incidência
/
Estudo observacional
/
Estudo prognóstico
Limite:
Humanos
Idioma:
Coreano
Revista:
Korean Circulation Journal
Ano de publicação:
1998
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS