Your browser doesn't support javascript.
loading
Effects of MR Parameter Changes on the Quantification of Diffusion Anisotropy and Apparent Diffusion Coefficient in Diffusion Tensor Imaging: Evaluation Using a Diffusional Anisotropic Phantom
Korean Journal of Radiology ; : 297-303, 2015.
Artigo em Inglês | WPRIM | ID: wpr-183063
ABSTRACT

OBJECTIVE:

To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. MATERIALS AND

METHODS:

Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, including voxel size, number of sensitivity encoding (SENSE) factor, echo time (TE), number of signal acquisitions, b-value, and number of diffusion gradient directions (NDGD), one-at-a-time in a stepwise-incremental fashion. We repeated the entire series of DTI scans thrice. The coefficients of variation (CoV) were evaluated for FA and ADC, and the correlation between each MR imaging parameter and the corresponding FA and ADC was evaluated using Spearman's correlation analysis.

RESULTS:

The capillary array phantom CoVs of FA and ADC were 7.1% and 2.4%, respectively. There were significant correlations between FA and SENSE factor, TE, b-value, and NDGD, as well as significant correlations between ADC and SENSE factor, TE, and b-value.

CONCLUSION:

A capillary array phantom enables repeated measurements of FA and ADC. Both FA and ADC can vary when certain parameters are changed during diffusion experiments. We suggest that the capillary array phantom can be used for quality control in longitudinal or multicenter clinical studies.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Projetos de Pesquisa / Anisotropia / Imagens de Fantasmas / Imagem de Difusão por Ressonância Magnética / Imagem de Tensor de Difusão / Razão Sinal-Ruído Tipo de estudo: Ensaio Clínico Controlado Limite: Humanos Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Projetos de Pesquisa / Anisotropia / Imagens de Fantasmas / Imagem de Difusão por Ressonância Magnética / Imagem de Tensor de Difusão / Razão Sinal-Ruído Tipo de estudo: Ensaio Clínico Controlado Limite: Humanos Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2015 Tipo de documento: Artigo