Your browser doesn't support javascript.
loading
Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions
Imaging Science in Dentistry ; : 145-151, 2013.
Artigo em Inglês | WPRIM | ID: wpr-188968
ABSTRACT

PURPOSE:

This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. MATERIALS AND

METHODS:

Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually.

RESULTS:

The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites.

CONCLUSION:

The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Dente / Filme para Raios X / Interpretação de Imagem Radiográfica Assistida por Computador / Resinas Compostas / Radiografia Dentária Digital / Esmalte Dentário / Dentina / Alumínio / Dente Molar Limite: Humanos Idioma: Inglês Revista: Imaging Science in Dentistry Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Dente / Filme para Raios X / Interpretação de Imagem Radiográfica Assistida por Computador / Resinas Compostas / Radiografia Dentária Digital / Esmalte Dentário / Dentina / Alumínio / Dente Molar Limite: Humanos Idioma: Inglês Revista: Imaging Science in Dentistry Ano de publicação: 2013 Tipo de documento: Artigo