Your browser doesn't support javascript.
loading
Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in 13N-Ammonia PET / 핵의학분자영상
Nuclear Medicine and Molecular Imaging ; : 194-200, 2007.
Artigo em Coreano | WPRIM | ID: wpr-189511
ABSTRACT

PURPOSE:

13N-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study.

METHODS:

Twelve patients (11 males, 1 female, 57.9+/-8.6 years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min 5 sec X 12, 10 sec X 6, 20 sec X 3, and 30 sec X 6) were initiated simultaneously with bolus injection of 11 MBq/kg 13N-ammonia to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used.

RESULTS:

There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments.

CONCLUSIONS:

Corrected and translated MPS as its characteristics using 13N-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Perfusão / Doença da Artéria Coronariana / Miocárdio Tipo de estudo: Estudo prognóstico Limite: Feminino / Humanos / Masculino Idioma: Coreano Revista: Nuclear Medicine and Molecular Imaging Ano de publicação: 2007 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Perfusão / Doença da Artéria Coronariana / Miocárdio Tipo de estudo: Estudo prognóstico Limite: Feminino / Humanos / Masculino Idioma: Coreano Revista: Nuclear Medicine and Molecular Imaging Ano de publicação: 2007 Tipo de documento: Artigo