Damage to an Endotracheal Tube during Lefort I Osteotomy: A case report / 대한마취과학회지
Korean Journal of Anesthesiology
; : 516-519, 2007.
Article
em Ko
| WPRIM
| ID: wpr-193258
Biblioteca responsável:
WPRO
ABSTRACT
In maxillofacial surgery endotracheal tube provides patent airway and prevents patient from aspirating the blood. But serious complications such as tube obstruction or injury have been reported. In this case, endotracheal tube injury by surgical saw during Lefort I osteotomy occurred. We could not exchange the defective tube for a good one using laryngoscope or fiberoptic bronchoscope due to edema and blood in nostril and oral cavity. We didn't have any tube exchanger available too. Therefore, to provide patent and safe airway, we packed gauze around the lacerated part of tube, provided positive end expiratory pressure ventilation and increased oxygen flow. After anesthesia, the damaged tube was safely removed and there were no respiratory complications.
Palavras-chave
Texto completo:
1
Índice:
WPRIM
Assunto principal:
Osteotomia
/
Oxigênio
/
Cirurgia Bucal
/
Ventilação
/
Respiração com Pressão Positiva
/
Broncoscópios
/
Laringoscópios
/
Edema
/
Anestesia
/
Boca
Limite:
Humans
Idioma:
Ko
Revista:
Korean Journal of Anesthesiology
Ano de publicação:
2007
Tipo de documento:
Article