Aortic injury associated with trocar insertion during laparoscopic-assisted vaginal hysterectomy: A case report
Anesthesia and Pain Medicine ; : 159-161, 2010.
Artigo em Inglês | WPRIM | ID: wpr-193390
ABSTRACT
Aortic injury during laparoscopic procedures is a rare but life-threatening complication if not recognized and swiftly treated. We report our experience with a 47-year-old woman presenting with an aortic puncture of the anterior wall from a trocar insertion during a laparoscopic-assisted vaginal hysterectomy (laparoscopic hysterectomy). Diagnosis was delayed because of the limited vision of the laparoscope and the tamponade effect produced by the pneumoperitoneum. Anesthesiologists should be aware of the risk of iatrogenic major vessel injury during trocar insertion.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Pneumoperitônio / Instrumentos Cirúrgicos / Visão Ocular / Punções / Laparoscópios / Glicosaminoglicanos / Histerectomia Vaginal Limite: Feminino / Humanos Idioma: Inglês Revista: Anesthesia and Pain Medicine Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Pneumoperitônio / Instrumentos Cirúrgicos / Visão Ocular / Punções / Laparoscópios / Glicosaminoglicanos / Histerectomia Vaginal Limite: Feminino / Humanos Idioma: Inglês Revista: Anesthesia and Pain Medicine Ano de publicação: 2010 Tipo de documento: Artigo