Your browser doesn't support javascript.
loading
Interpretation of Frequency Doubling Technology Perimeter in Diagnosis of Glaucoma and Glaucoma Suspect
Journal of the Korean Ophthalmological Society ; : 1096-1105, 2007.
Artigo em Coreano | WPRIM | ID: wpr-194060
ABSTRACT

PURPOSE:

To find applicable parameters of the frequency doubling technology perimeter (FDP), which is known to be useful in detecting early visual field loss.

METHODS:

The subjects were 65 eyes of normal individuals, 58 eyes of glaucoma suspects, and 37 eyes of glaucoma patients. FDP (MD, PSD), SAP (MD, PSD, CPSD), and 5 parameters of OCT were analyzed. The receiver operating characteristic (ROC) curve, sensitivity, and specificity of each parameter were evaluated, and the comparison of FDP parameters by Pearson's chi-square was made between the glaucoma suspect group and the normal group. The same comparison was made among the normal+glaucoma suspect and glaucoma group.

RESULTS:

In discriminating between the normal and glaucoma suspect groups, the FDP-PSD revealed an AUC of 0.745 (cutoff 3.17dB), which was significantly larger than that of SAP-PSD with an AUC of 0.660 (cutoff 1.73dB). In comparing FDP, PSD by Anderson criteria was most reliable with a hit ratio of 0.732. On the other hand, in discriminating among the normal+glaucoma suspect group and glaucoma group, the SAP-PSD showed an AUC 0.971 (cutoff 2.92dB), much larger than the FDP-PSD with an AUC of 0.863 (cutoff 3.78dB). In addition, in comparing the parameters of FDP by Pearson chi-square, PSD 1% was the most reliable with a hit ratio of 0.813.

CONCLUSIONS:

FDP is a valuable screening tool in detecting early visual field loss. PSD by Anderson criteria can be a reliable parameter for the diagnosis of pre-perimetric glaucoma, and PSD 1% can be used in the discrimination of perimetric glaucoma.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Campos Visuais / Glaucoma / Programas de Rastreamento / Curva ROC / Sensibilidade e Especificidade / Área Sob a Curva / Diagnóstico / Discriminação Psicológica / Mãos Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Estudo de rastreamento Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2007 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Campos Visuais / Glaucoma / Programas de Rastreamento / Curva ROC / Sensibilidade e Especificidade / Área Sob a Curva / Diagnóstico / Discriminação Psicológica / Mãos Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Estudo de rastreamento Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2007 Tipo de documento: Artigo