Three-year follow-up of Clinical Results after SI-30NB Intraocular Lens Implantation Through Temporal Clear Corneal Incision
Journal of the Korean Ophthalmological Society
;
: 645-650, 2000.
Artigo
em Coreano
| WPRIM
| ID: wpr-194615
ABSTRACT
We examined the clinical results of silicone IOL[SI-30NB]for 3 years or more. A total of 50 eyes underwent phacoemulsification and foldable silicone posterior chamber lens implantation through 3.2 millimeter temporal clear corneal incision. Preoperative and post-operative intraocular pressure, visual acuity, corneal astigmatism and complications were evaluated. More than 94%of all cases showed best corrected visual acuity better than 20/40 and intraocular pressure was decreased for 2 months. At 1 day after operation, mean surgically induced astigmatism was minimal[0.64 +/-1.42]and recovered fast. Posterior capsular opacity was found in 26%;however, Nd-YAG laser capsulotomy was performed in 18%. In conclusion, foldable silicone lens implantation through 3.2 millimetertemporal clear corneal incision revealed a low incidence of complication, minimally induced astigmatism, and rapid visual rehabilitation.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Reabilitação
/
Astigmatismo
/
Silicones
/
Acuidade Visual
/
Incidência
/
Seguimentos
/
Facoemulsificação
/
Implante de Lente Intraocular
/
Lasers de Estado Sólido
/
Pressão Intraocular
Tipo de estudo:
Estudo de incidência
/
Estudo observacional
/
Estudo prognóstico
Idioma:
Coreano
Revista:
Journal of the Korean Ophthalmological Society
Ano de publicação:
2000
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS