Your browser doesn't support javascript.
loading
Calculation of the Cardiothoracic Ratio from Portable Anteroposterior Chest Radiography
Journal of Korean Medical Science ; : 1446-1453, 2011.
Artigo em Inglês | WPRIM | ID: wpr-197810
ABSTRACT
Cardiothoracic ratio (CTR), the ratio of cardiac diameter (CD) to thoracic diameter (TD), is a useful screening method to detect cardiomegaly, but is reliable only on posteroanterior chest radiography (chest PA). We performed this cross-sectional 3-phase study to establish reliable CTR from anteroposterior chest radiography (chest AP). First, CDChest PA/CDChest AP ratios were determined at different radiation distances by manipulating chest computed tomography to simulate chest PA and AP. CDChest PA was inferred from multiplying CDChest AP by this ratio. Incorporating this CD and substituting the most recent TDChest PA, we calculated the 'corrected' CTR and compared it with the conventional one in patients who took both the chest radiographies. Finally, its validity was investigated among the critically ill patients who performed portable chest AP. CDChest PA/CDChest AP ratio was {0.00099 x (radiation distance [cm])} + 0.79 (n = 61, r = 1.00, P < 0.001). The corrected CTR was highly correlated with the conventional one (n = 34, difference 0.00016 +/- 0.029; r = 0.92, P < 0.001). It was higher in congestive than non-congestive patients (0.53 +/- 0.085; n = 38 vs 0.49 +/- 0.061; n = 46, P = 0.006). Its sensitivity and specificity was 61% and 54%. In summary, reliable CTR can be calculated from chest AP with an available previous chest PA. This might help physicians detect congestive cardiomegaly for patients undergoing portable chest AP.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Tórax / Radiografia Torácica / Tomografia Computadorizada por Raios X / Estudos Transversais / Cardiomegalia / Sistemas Automatizados de Assistência Junto ao Leito / Dispneia / Coração Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Journal of Korean Medical Science Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Tórax / Radiografia Torácica / Tomografia Computadorizada por Raios X / Estudos Transversais / Cardiomegalia / Sistemas Automatizados de Assistência Junto ao Leito / Dispneia / Coração Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Journal of Korean Medical Science Ano de publicação: 2011 Tipo de documento: Artigo