The Use of Contrast in Caudal Epidural Injections under Image Intensifier Guidance: Is It Necessary?
Clinics in Orthopedic Surgery ; : 190-192, 2017.
Artigo em Inglês | WPRIM | ID: wpr-202490
ABSTRACT

BACKGROUND:

We investigated the value of using contrast as an additional aid to confirm the accuracy of needle placement for caudal epidural injections under intraoperative image intensifier guidance.

METHODS:

A total of 252 consecutive patients were included in this study. Their mean age was 46.7 years (range, 32 to 76 years). There were 133 males (53%) and 119 females (47%) over a 12-month period.

RESULTS:

Of the 252 consecutive procedures, the contrast enhanced image intensifier confirmed accurate needle placement on first attempt in 252 cases (100%). Needle resiting following the infiltration of contrast was required in 0 case.

CONCLUSIONS:

The results from this study demonstrate that a surgeon beyond the learning curve can accurately place caudal epidural injections using image intensification only, without the use of contrast.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Coluna Vertebral / Injeções Epidurais / Fluoroscopia / Curva de Aprendizado / Anestesia Caudal / Agulhas Tipo de estudo: Guia de Prática Clínica Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Coluna Vertebral / Injeções Epidurais / Fluoroscopia / Curva de Aprendizado / Anestesia Caudal / Agulhas Tipo de estudo: Guia de Prática Clínica Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2017 Tipo de documento: Artigo