Your browser doesn't support javascript.
loading
Percutaneous Transcholecystic Approach for an Experiement of Biliary Stent Placement: An Experimental Study in Dogs
Journal of the Korean Radiological Society ; : 543-549, 2002.
Artigo em Coreano | WPRIM | ID: wpr-208113
ABSTRACT

PURPOSE:

To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. MATERIALS AND

METHODS:

A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2, 4, and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrificed, and a pathologic examination was performed.

RESULTS:

Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks.

CONCLUSION:

Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-up period.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Cavidade Peritoneal / Peritonite / Bile / Ductos Biliares / Colangiografia / Stents / Drenagem / Seguimentos / Ultrassonografia / Elapidae Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico Limite: Animais Idioma: Coreano Revista: Journal of the Korean Radiological Society Ano de publicação: 2002 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Cavidade Peritoneal / Peritonite / Bile / Ductos Biliares / Colangiografia / Stents / Drenagem / Seguimentos / Ultrassonografia / Elapidae Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico Limite: Animais Idioma: Coreano Revista: Journal of the Korean Radiological Society Ano de publicação: 2002 Tipo de documento: Artigo