Your browser doesn't support javascript.
loading
Simultaneous Use of Both Bilateral Intralaminar and Pedicle Screws for C2 Stabilization
Asian Spine Journal ; : 789-793, 2015.
Artigo em Inglês | WPRIM | ID: wpr-209946
ABSTRACT
Four patients underwent stabilization surgery using both bilateral C2 pedicle screw (PS) and intralaminar screw (LS). Neural and vascular injury resulting from incorrect screw placement was assessed using computed tomography (CT). The evaluation of bone union was assessed by lateral flexion-extension X-ray films and CT. The symptoms were improved in all patients. There were no intraoperative complications. Furthermore, there were no cases of neurological worsening or vascular injury from incorrect screw placement. Failure of instrumentation or screw loosening during the follow-up period did not occur in any of the patients. All cases had accomplished bone union at the final follow-up. Theoretically, the stabilization technique using both bilateral C2 PS and LS at the same time can provide more stability than any other single technique. Simultaneous use of both bilateral C2 PS and LS is potentially a good choice for surgical repair.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Fusão Vertebral / Filme para Raios X / Seguimentos / Lesões do Sistema Vascular / Complicações Intraoperatórias Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Asian Spine Journal Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Fusão Vertebral / Filme para Raios X / Seguimentos / Lesões do Sistema Vascular / Complicações Intraoperatórias Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Asian Spine Journal Ano de publicação: 2015 Tipo de documento: Artigo