Your browser doesn't support javascript.
loading
Structural and Functional Relationships in Glaucoma Using Standard Automated Perimetry and the Humphrey Matrix
Korean Journal of Ophthalmology ; : 176-182, 2009.
Artigo em Inglês | WPRIM | ID: wpr-210148
ABSTRACT

PURPOSE:

To evaluate and compare correlations between structural and functional loss in glaucoma as assessed by optical coherence tomography (OCT), scanning laser polarimetry (GDx VCC, as this was the model used in this study), standard automated perimetry (SAP), and the Humphrey Matrix (Matrix).

METHODS:

Ninety glaucomatous eyes identified with SAP and 112 eyes diagnosed using Matrix were independently classified into six subgroups, either S1/M1 (MD>-6dB), S2/M2 (-12retinal nerve fiber layer (RNFL) thickness and percentage of abnormal classifications using the internal normative databases of OCT and GDx VCC were compared among the six subgroups.

RESULTS:

In the SAP subgroups, RNFL thickness values obtained by OCT in the nasal and temporal quadrants and the inferior averages of GDx VCC did not differ between the S1 and S2 subgroups (p=0.137, 0.738 and 0.149, respectively). In the Matrix subgroups, no measurement parameters differed between the M1 and M2 groups except for the overall mean and average inferior RNFL thickness given by OCT and the NFI values of GDx VCC (p=0.013, 0.016 and 0.029, respectively). When abnormal classifications were compared, all measurement parameters, without exception, were significantly different in both the SAP and the Matrix subgroups.

CONCLUSIONS:

SAP subgroups showed a good correlation of structural and functional defects when assessed using OCT and GDx VCC. These correlations were weaker in the Matrix subgroups, especially in the early stages of glaucoma.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Retina / Automação / Glaucoma / Tomografia de Coerência Óptica / Polarimetria de Varredura a Laser / Testes de Campo Visual / Fibras Nervosas Tipo de estudo: Estudo prognóstico Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Korean Journal of Ophthalmology Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Retina / Automação / Glaucoma / Tomografia de Coerência Óptica / Polarimetria de Varredura a Laser / Testes de Campo Visual / Fibras Nervosas Tipo de estudo: Estudo prognóstico Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Korean Journal of Ophthalmology Ano de publicação: 2009 Tipo de documento: Artigo