Cerebral Ischemia Detected with Diffusion-Weighted MR Imaging after Protected Carotid Artery Stenting: Comparison of Distal Balloon and Filter Device
Korean Journal of Radiology
;
: 276-285, 2007.
Artigo
em Inglês
| WPRIM
| ID: wpr-211226
ABSTRACT
OBJECTIVE:
The aim of this study was to examine the incidence of ischemia during protected carotid artery stenting (CAS) as well as to compare the protective efficacy of the balloon and filter devices on diffusion-weighted MR imaging (DWI). MATERIALS ANDMETHODS:
Seventy-one consecutive protected CAS procedures in 70 patients with a severe (> 70%) or symptomatic moderate (> 50%) carotid artery stenosis were examined. A balloon device (PercuSurge GuardWire) and a filter device (FilterWire EX/EZ, Emboshield) was used in 33 cases (CAS-B group) and 38 cases (CAS-F group) to prevent distal embolization, respectively. All the patients underwent DWI within seven days before and after the procedures. The number of new cerebral ischemic lesions on the post-procedural DWI were counted and divided into ipsilateral and contralateral lesions according to the relationship with the stenting side.RESULTS:
New cerebral ischemic lesions were detected in 13 (39.4%) out of the 33 CAS-Bs and in 15 (39.5%) out of the 38 CAS-Fs. The mean number of total, ipsilateral and contralateral new cerebral ischemic lesion was 2.39, 1.67 and 0.73 in the CAS-B group and 2.11, 1.32 and 0.79 in the CAS-F group, respectively. No statistical differences were found between the two groups (p = 0.96, 0.74 and 0.65, respectively). The embolic complications encountered included two retinal infarctions and one hemiparesis in the CAS-B group (9.09%), and one retinal infarction, one hemiparesis and one ataxia in the CAS-F group (7.89%). There was a similar incidence of embolic complications in the two groups (p = 1.00).CONCLUSION:
The type of distal protection device used such as a balloon and filter does not affect the incidence of cerebral embolization after protected CAS.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Paresia
/
Índice de Gravidade de Doença
/
Oclusão da Artéria Retiniana
/
Stents
/
Isquemia Encefálica
/
Endarterectomia das Carótidas
/
Estenose das Carótidas
/
Implante de Prótese Vascular
/
Embolia Intracraniana
/
Oclusão com Balão
Limite:
Adulto
/
Idoso
/
Aged80
/
Feminino
/
Humanos
/
Masculino
Idioma:
Inglês
Revista:
Korean Journal of Radiology
Ano de publicação:
2007
Tipo de documento:
Artigo
Similares