Your browser doesn't support javascript.
loading
Laryngeal Mask Airway Insertion in Adults: Comparison between Fully Deflated and Partially Inflated Technique
Yonsei Medical Journal ; : 747-751, 2013.
Artigo em Inglês | WPRIM | ID: wpr-211911
ABSTRACT

PURPOSE:

The laryngeal mask airway (LMA) is a supraglottic airway device designed to seal around the laryngeal inlet. A controlled study was designed to compare the effectiveness and complications in inserting the LMA when the cuff is fully deflated and partially inflated. MATERIALS AND

METHODS:

American Society of Anesthesiologists physical status I or II 172 female patients scheduled for gynecologic procedures were included in this study. Patients were randomly allocated into one of the two groups; fully deflated (n=86) and partially inflated group (n=86). A size #4 LMA was inserted. The number of attempts, time taken for successful insertion, grade of leak, grade of fiberoptic view, and complications were evaluated.

RESULTS:

All 172 patients completed the study protocol. The number of attempts, time taken for successful insertion, and grade of leak were not significantly different between the two groups. The grade of fiberoptic view and complications were lower in the fully deflated group.

CONCLUSION:

The fully deflated method is more accurate and safe because of better fiberoptic view and lesser complications than the partially inflated group.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Máscaras Laríngeas / Manuseio das Vias Aéreas Limite: Adulto / Feminino / Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Máscaras Laríngeas / Manuseio das Vias Aéreas Limite: Adulto / Feminino / Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo