Your browser doesn't support javascript.
loading
Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems
The Journal of Advanced Prosthodontics ; : 439-448, 2016.
Artigo em Inglês | WPRIM | ID: wpr-213531
ABSTRACT

PURPOSE:

The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND

METHODS:

Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a 5° convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed.

RESULTS:

The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and 117 µm and those from Zirkonzahn system were between 111 and 115 µm. Marginal discrepancies of copings made with Ceramil system were between 101 and 131 µm and those from Zirkonzahn system were between 116 and 131 µm.

CONCLUSION:

Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próteses e Implantes / Silício / Silicones / Técnicas de Réplica / Coroas / Porcelana Dentária / Arcada Osseodentária / Dente Molar Tipo de estudo: Guia de Prática Clínica Idioma: Inglês Revista: The Journal of Advanced Prosthodontics Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Próteses e Implantes / Silício / Silicones / Técnicas de Réplica / Coroas / Porcelana Dentária / Arcada Osseodentária / Dente Molar Tipo de estudo: Guia de Prática Clínica Idioma: Inglês Revista: The Journal of Advanced Prosthodontics Ano de publicação: 2016 Tipo de documento: Artigo