Your browser doesn't support javascript.
loading
Successful removal of kinked J-guide wire under fluoroscopic guidance during central venous catheterization: A case report / 대한마취과학회지
Article em En | WPRIM | ID: wpr-224610
Biblioteca responsável: WPRO
ABSTRACT
Guidewire-associated complications that occur during the process of central venous catheterization include its kinking, looping, knotting and breakage. The removal of a looped or knotted guidewire is problematic because it can cause vessel damage, major hemorrhage, or embolization of a fractured guidewire. We report a case of guidewire kinking and its successful removal under fluoroscopic guidance.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Cateterismo Venoso Central / Cateteres Venosos Centrais / Glicosaminoglicanos / Hemorragia Tipo de estudo: Guideline Idioma: En Revista: Korean Journal of Anesthesiology Ano de publicação: 2011 Tipo de documento: Article