Hounsfield Number Measurement after a Uterine Fibroid Embolization: Significance as a Predictive Factor of Embolization Success
Journal of the Korean Radiological Society
;
: 13-20, 2008.
Artigo
em Coreano
| WPRIM
| ID: wpr-225360
ABSTRACT
PURPOSE:
To assess the usefulness of the Hounsfield number, measured by a non-contrast enhanced pelvic CT, after a uterine artery embolization as an index of the successful outcome of a uterine fibroid embolization (UFE). MATERIALS ANDMETHODS:
The study subjects included 15 women (age range 28-49 years, mean age 36.4 years) diagnosed with symptomatic uterine myomas and seen from March 2003 to August 2005. A non-contrast enhanced pelvic CT scan was performed six hours after a uterine artery embolization. The global and maximal CT numbers were measured for each myoma. In addition, a pelvic MRI was performed to measure the volume of each myoma prior to and 6 months after the UFE. The relationship between fibroid volume reduction and the global CT number were prospectively analysed.RESULTS:
The mean global CT number was 91.25 HU in Group I and 40.8 HU in Group II. Further, the mean fibroid volume reduction rate was 73% in Group I and 10% in Group II (p < 0.05).CONCLUSION:
The global CT number measured by a non-contrast enhanced pelvic CT is a useful predictive factor of a successful uterine fibroid embolization.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Neoplasias Uterinas
/
Tomografia Computadorizada por Raios X
/
Radiologia Intervencionista
/
Estudos Prospectivos
/
Embolização Terapêutica
/
Embolização da Artéria Uterina
/
Leiomioma
/
Mioma
Tipo de estudo:
Estudo observacional
/
Estudo prognóstico
Limite:
Feminino
/
Humanos
Idioma:
Coreano
Revista:
Journal of the Korean Radiological Society
Ano de publicação:
2008
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS